# CI checks
| Check | What it fails | Since |
|---|---|---|
| kill by exact command or pid file (owed as a check) | 6 October 2026, 21:09Z: a Mac-side `pkill -f <log file name>` matched nothing (the log name was a redirect, not part of the command line), the roll-everything script lived on and wiped a box it had been told to hold. Rule: a job is stopped by its pid file (`tools/fleet/fleet-bg.sh start|stop <name>`) or by a pattern anchored on its exact command line (`^python3 -u /root/fleet/in/box-prover.py`), never by a word that may or may not appear in it. The check that flags a `pkill -f`/`pgrep -f` whose literal is a path or a name that never starts a command line is owed to the CI lane |