windows
|
0.3.23: an install over the running app returns the new version (PC 2, 7 October 2026, 20:54 BST: a job's silent 0.3.22 install quit the engine through api/quit, the 0.3.21 window host's restart ladder started the old engine 10 s later, Inno could not replace the locked host and every file stayed 0.3.21). (1) The installer's stop step ends the window host FIRST by its path, then asks the engine to quit, then ends what is left by path, and waits up to 30 s for every exe to open for write, naming the one that stays locked; CloseApplicationsFilter and SetupMutex set. (2) The engine prints "EXIT update" when an installer or its own OTA stopped it and the host then ends itself instead of restarting; the installer writes install-running.flag beside app.url for its whole run and the update helper's every launch and the host's restart ladder hold while it is there (a marker older than 15 min is a dead installer, ignored with a FAULT line). Tests known-failed first: exit_line, relaunch_allowed with tonight's sequence, the stop step's order and unlock wait, the host's and the installer's text
|
2026-10-07 20:14:08 +00:00 |