igneum/app
igneum-labs 59edaad1e4 first-block-21, main's reading "seen once": the first-block card waits until a window has shown it. The flag first_block_shown is set when the page reports the card displayed or dismissed (POST api/card/seen with the milestone's count and at, ladder.rs card_seen; the window hiding to the tray with the card up counts as the dismiss), never when the card is raised; an unseen card survives restarts and auto-updates (start_run drops a card only once milestone_seen), so a first block found overnight greets the miner the first time they open the app and never again. Every other rule stands: the lifetime count 0 to 1 raises it, identities and card swaps leave it, a kept directory at 0 shows it on the first block, a count that starts over raises nothing, a 0.3.20 record (schema 0, no flag) whose first block already came takes the flag and loses its card. The view trusts a 0.3.21 engine (the ladder carries first_block_shown) and keeps the uptime refusal only against a 0.3.20 engine. Tests: ladder.rs eight (a_first_block_found_with_no_window_greets_the_miner_at_the_first_open_and_never_again added: no window, a restart, the first open shows it once, a second open does not; the round-trip helper gets one temp dir per call, the shared path let parallel tests wipe each other's file), the view test re-cut, the mock's firstblock card unseen (the capture's mock log shows the page's api/card/seen). Lines: build-2 app gate 255 + 32 + 8; UI 67; pre-push 56 green; captures re-taken to ~/Desktop/igneum-previews-2026-10-07/first-block.
Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com>
2026-10-07 15:09:20 +00:00
..
igneum-app first-block-21, main's reading "seen once": the first-block card waits until a window has shown it. The flag first_block_shown is set when the page reports the card displayed or dismissed (POST api/card/seen with the milestone's count and at, ladder.rs card_seen; the window hiding to the tray with the card up counts as the dismiss), never when the card is raised; an unseen card survives restarts and auto-updates (start_run drops a card only once milestone_seen), so a first block found overnight greets the miner the first time they open the app and never again. Every other rule stands: the lifetime count 0 to 1 raises it, identities and card swaps leave it, a kept directory at 0 shows it on the first block, a count that starts over raises nothing, a 0.3.20 record (schema 0, no flag) whose first block already came takes the flag and loses its card. The view trusts a 0.3.21 engine (the ladder carries first_block_shown) and keeps the uptime refusal only against a 0.3.20 engine. Tests: ladder.rs eight (a_first_block_found_with_no_window_greets_the_miner_at_the_first_open_and_never_again added: no window, a restart, the first open shows it once, a second open does not; the round-trip helper gets one temp dir per call, the shared path let parallel tests wipe each other's file), the view test re-cut, the mock's firstblock card unseen (the capture's mock log shows the page's api/card/seen). Lines: build-2 app gate 255 + 32 + 8; UI 67; pre-push 56 green; captures re-taken to ~/Desktop/igneum-previews-2026-10-07/first-block. 2026-10-07 15:09:20 +00:00
mac Miner UI 4 (b): a screenshot from the machine itself: POST /api/shot asks the window host over the SHOT line; the Mac host snapshots the web view, the Windows host captures through WebView2, both to <data root>/shots/; app-shot.ps1 plus a collect glob bring it back. 152 app tests on the box. 2026-10-06 23:14:29 +00:00
windows MF-11 update-return (0.3.21), the app half on release-0.3.21: the Windows update helper owns the return (the exe set kept beside the app, the app launched by the helper, api/state polled 120 s, the kept set restored when nothing answers, one intake line either way; the installer stays silent under /IGNOTA=2), the window host restarts a dead engine and answers the Restart Manager, the first act after an update is the read-back line and a FAULT pc-restart line when the PC came up from a power loss; the tuner never asks above a card's measured efficient point (the 5090 at 308 W, floored at the vendor's 400 W) unless Power control is on and the user raised the cap, and a refused cap is asked again at 2 and 10 min then reported as FAULT power-cap; the job-channel ping on every wake request (7 October 2026, PC 2 lost power at 10:46Z; the relay half stays on update-return) 2026-10-07 14:29:41 +00:00