miner-faults MF-11 corrected: the machine goes silent and nothing tells anyone (PC 2's power loss, not the update-now); the silence watch per machine and the relay agent as a service
Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com>
This commit is contained in:
parent
8e873fe66c
commit
951cfbf9a5
1 changed files with 1 additions and 1 deletions
|
|
@ -32,7 +32,7 @@ Standing rules behind every row (branch `miner-reliability`, off `release-0.3.19
|
|||
| MF-8 | 7 Oct 2026, every node build from 10db4b61 on a kept 0.3.17 datadir | "Node refuses its own kept datadir after an update": the app updates, the node dies at once (`DeserializationError(Io(Kind(UnexpectedEof)))` at `consensus/src/model/stores/virtual_state.rs:250`), the app restarts it in a loop, the miner never starts | `silent: bool` was added to `BlockRewardData` under `serde(default)` (10db4b61, the 0.3.16 vote-or-burn commit) and bincode ignores serde defaults, so the old row reads short; no canary saw it because every canary wiped. Fixed as ledger N13 on `release-0.3.20-node` b7cc37e7 (the store reads the v1 row and rewrites it) | Every schema change to a stored row ships with a versioned read path (the old shape read, rewritten in the new one); every release's gate starts the pinned binary on a COPY of a standing box's datadir, Linux-shaped and Windows-shaped (a copy of PC 2's), with the rewrite line or the synced line as the pass; the app never asks the user to wipe: a node that dies inside 10 s of its start is reported home (`node-exit` FAULT line) and the row says "the node cannot read its data after the update; the team has the report" | The node line's N13 test (the v1 row read and rewritten); the gate's kept-datadir start on both shapes; the injector step `kept-datadir` is OWED (a datadir from the previous release under the new binary needs a previous-release node on the pod; the shape is: run the old node to a few hundred blocks, stop it, start the new one on its datadir, pass on the synced line) | `canary kept-datadir start PASS (linux, windows)` in every cut's plan; `LG-4` row kept=true beside the nine wiped |
|
||||
| MF-9 | 7 Oct 2026, release-0.3.20-node b7cc37e7, the mixed-version gate | A node that stops slower than its restart: the restart died at once on the datadir LOCK of the stopping node | The listener watchdog slept its whole 10 s poll before it checked the shutdown flag, so a stop took up to 10 s while the app's restart followed inside it | Every poll loop in the node returns the moment shutdown is set (a `select` on the shutdown signal, never a sleep then a check); "a shutdown returns within one second" is a named gate of every release beside the kept-datadir start; the app's `stop_node` waits for the exit before the restart (`restart_node` schedules the start after the stop returns) | The node line's shutdown-latency test (stop at a random moment of the poll, return under 1 s); the mixed-version gate's restart case; `app-run.mjs` step `node-silent` reads the restart-to-synced seconds | `node shutdown under 1 s PASS` in every cut's plan |
|
||||
| MF-10 | 7 Oct 2026, the prover roll (3080, 3090, 4070, 5090) | Every proof fails in 12 s with `CudaRustError: named symbol not found`; the miner never notices and the box proves nothing for hours | The prover's `sp1-gpu-server` was built for another card's compute capability (sm_86 on the 3080 and 3090, sm_89 on the 4070, sm_120 on the 5090), so every kernel load fails the same way | The prover reads the card's compute capability at start (`nvidia-smi --query-gpu=compute_cap`) and refuses to start a server that does not match, with the reason on the prover tile and a FAULT line home ("the proving server is built for sm_89, this card is sm_120"); a proof that fails inside 15 s with the symbol error marks the server mismatched the same way; the 0.3.21 kit ships one server per architecture chosen at install, or a fat binary | the prover's compute-capability test (a server named for sm_89 refused on a card that reads 12.0); the fleet roll's paired line per box | `prover server matches the card PASS` per box in the roll, beside the kept-datadir and the shutdown gates |
|
||||
| MF-11 | 7 Oct 2026, PC 2 (1ccfe586), the 0.3.19 update-now at 10:34Z | The app did not come back after the update: the machine has been silent since, and its relay agent died with the app (last seen 6 October), so neither a signed job nor a relay task reaches it; the restart path today is a click on the PC | The update-now relaunch did not return the app (cause with the UI lane); the relay agent runs under the app's own lifetime instead of beside it | An update-now that does not read the new version back within 10 minutes posts a FAULT line home through whatever still runs (the relay agent, the OTA helper's own upload) and the agent restarts the app; the relay agent runs as a service that survives the app (the relay lane, 0.3.21); the app's first act after an update is the read-back line "app <version> up, node <commit>" to the intake | the OTA helper's read-back test (a relaunch that does not answer `api/state` inside 10 minutes writes the FAULT line and asks the agent); the relay lane's service test (the app killed, the agent still answers) | `update-now read-back PASS` per box in the rollout table; PC 2's own line when it is back |
|
||||
| MF-11 | 7 Oct 2026, PC 2 (1ccfe586), silent 10:46Z to 13:38Z (Kernel-Power 41 and 6008 "unexpected shutdown", no bugcheck, no dump; two such events on that box today; the 0.3.19 update-now at 10:34:38Z had returned cleanly, so the update is not the cause) | The machine goes silent and nothing tells anyone: no job, no relay task, no line reaches the team for three hours; the restart path today is a hand at the PC | A power loss took the whole PC; the relay agent runs under the app's lifetime instead of beside it, and no watcher raises a line when a machine stops reporting | An app or agent that does not report within 10 minutes raises a line somewhere that still runs (the intake's own silence watch per machine id: a FAULT line "no report from <id8> for N min" to the team's channel); the relay agent runs as a service that survives the app and restarts the app on boot (the relay lane, 0.3.21); the app's first act after any start is the read-back line "app <version> up, node <commit>" to the intake | the intake's silence-watch test (a machine whose last upload is older than 10 min is listed once); the relay lane's service test (the app killed, the agent still answers; the box rebooted, the app back) | `silence watch` line in the team channel per quiet box; PC 2's own line when it is back. Note for MF-8: PC 2's datadir, cut off mid-write twice by power loss, started clean on c4459193 (the PC 2 job's PASS) |
|
||||
| MF-12 | 7 Oct 2026, the fleet lane's ten-member pool window (ten rented 3070s, `igneum-miner mine none ... --pool pool-1:4463`, daemon 03457d96, miner 9829bdf7); the pool lane's row (its branch pool-mf-row 343dd83b called it MF-11; renumbered here so the register has one number per class) | A pool member without a node of its own stopped hashing at the epoch boundary 78 to 79 and never resumed: every member printed `POOL SEEDS epoch c1fc2c7c... class 3` and `worker: info prepare started for epoch c1fc2c7c160f8a19 ... (NVRTC sm_86 in the background)`, that prepare never answered `prepared` or `prepare-failed`, the worker sat at 0 percent GPU serving the epoch-78 pack, the daemon's STATUS read `workers=9 accepted=0`, vardiff eased every member from shift 10 to 27 with no share, and no error line was printed anywhere (12:50Z to 13:08Z; cleared only by a restart on a pack exported from pool-1's node) | Open (the pool lane): the member's `prepare` line is the solo miner's shape (`igneum/miner/src/pool.rs` `prepare_line`), so the fault is either the member's pack write under `--prepare-packs` or the worker's NVRTC prepare on that pack; the fleet lane holds the worker lines and a solo control on the same box is the split | A member that sent a `prepare` and heard nothing for 120 s treats it as `prepare-failed`: it re-exports the pack, re-sends the prepare once, and on a second silence restarts its worker with the reason on its STATUS line and in the pool's `stats`; the pool daemon flags a member whose accepted count stays 0 across an epoch roll (`EPOCH STALL` line, the member's `online` false on the page); no pool member is ever silent across a boundary | owed (the pool lane): the pool's measure harness crosses two epoch boundaries with a member on `none` and a worker whose prepare is held (the stand-in worker of `tools/reliability/fake-worker.mjs`), and reads shares on both sides | the ten-member window's capture: every member's accepted count rises across every boundary the window crosses |
|
||||
| MF-3 | 7 Oct 2026, PC 1, Intel Arc | The Intel driver's first install did not bind: the device sat in Code 12 at install time; the card never mined until a reboot | A driver installed while the device reports a problem code (12, 43, 31) does not bind; nothing re-scanned the device afterwards, and the app only re-enumerates | The app re-enumerates every 60 s and starts the worker the minute the OS drives the card (`hotplug::diff` recovered / revived, `settle_new`); the row says what to do while it does not ("reboot with the card attached; if it persists, reinstall the driver with the card attached"); a Windows host asks for a re-scan (`pnputil /scan-devices`) after a problem code is seen, every 5 minutes, at most 6 times (follow-up, host side) | `hotplug` test `a_driven_card_that_turns_faulty_is_errored_and_recovers_later`; `app-run.mjs` step `card-appears` (a card listed after 2 minutes starts without a tap) | `app-run card-appears PASS` |
|
||||
|
||||
|
|
|
|||
Loading…
Reference in a new issue