bench log + plan: PC 1 run 1 aborted by the 0.3.11 update 47 s in, the before snapshots of both cards, the AMD offset-range finding and its consequence per tier
Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com>
This commit is contained in:
parent
054e0416d8
commit
2f5e04cd8d
2 changed files with 16 additions and 3 deletions
|
|
@ -1624,4 +1624,13 @@ Branch `ember-tune` (54ff1bc), docs/plans/ember-tune.md. Every card tuned for MH
|
|||
|
||||
**Tier consequences** (docs/plans/ember-tune.md section 7): a 9-step full tune costs about 12 minutes once and 3 minutes a week per card, under 1% of the hour, the worker never stops; a rig tunes one card at a time and every card of a known model after the first takes the 3-minute confirm; a pool user gives up the same 1% of shares at most; Apple silicon and AMD on Linux measure only and the row says so.
|
||||
|
||||
(The PC 1 run's numbers follow below when the job reports.)
|
||||
**The PC 1 run, 22:30 UTC (job ember-tune-pc1-1, engine aeea3228..., PC 1 on 0.3.10):** the job published at 22:29:40Z, the installed app stopped its miners and started the second engine at 22:30:21Z, and at 22:31:06Z the installed app quit for the 0.3.11 update-now (its log: `job ember-tune-pc1-1: aborted (the app is quitting)`), taking the second engine with it 47 s in, before any step. Nothing was set. What the run did record, the "before" snapshots with the miners stopped:
|
||||
|
||||
| Card | Read back at 22:30:20Z | Meaning |
|
||||
|---|---|---|
|
||||
| RTX 5090 (driver 617.14) | limit 450 W of 575 W default (min 400, max 600), draw 259.9 W idle-after-stop, core 2,850 MHz, `clocks.max.gr` 3,090 MHz, memory 14,001 MHz | the two-knob plan for this card is 5 power steps (575, 518, 460, 403, 400 W) and 4 clock steps (2,781, 2,472, 2,163, 1,854 MHz); it needs the one administrator prompt (Power control) |
|
||||
| RX 9070 XT (bus 98, present again) | `tune 1 ... gmax 0 gmax_range -500 1000 plimit 0 plimit_range -30 10 factory 1 ok` | the helper's clock range is an OFFSET from stock in MHz, not a ceiling: a probe reading it as a 1,000 MHz maximum would have asked for `--set-gmax 900`, an overclock. Fixed at 054e041: an offset range closes the clock knob (until the stock clock is known) and the power ladder runs on the percent scale bounded by the range, so the 9070 XT's plan is 100, 90, 80, 70% (the -30 floor), 4 steps |
|
||||
| Radeon(TM) Graphics (integrated) | `tune 0 ... gmax - ... factory 0 ok` | no manual tuning: measure only, and it is off by default anyway |
|
||||
|
||||
Consequence for the tiers: an AMD card is tuned on its power limit alone until its stock core clock is read (a 9070 XT at -30% is the floor the driver allows, 4 steps, 5 minutes); every NVIDIA card's two-knob plan waits on the user's one click on Power control; the re-run on PC 1 follows the 0.3.11 rollout (the update clears the jobs folder, so the engine and the helper are fetched again), with the scheduler's slot.
|
||||
|
||||
|
|
|
|||
|
|
@ -29,7 +29,7 @@ prompt) for both knobs; off, it measures only.
|
|||
| Vendor | Power limit | Core clock cap | Memory clock | How | Rights |
|
||||
|---|---|---|---|---|---|
|
||||
| NVIDIA | `nvidia-smi -pl <W>`, percent of the default, inside `power.min_limit` and `power.max_limit` | `nvidia-smi -lgc 0,<MHz>`, percent of `clocks.max.gr`; `-rgc` = unlocked | never touched (`-lmc` is not used); read back as `clocks.mem` | directly when the engine is elevated, else the one-prompt helper (`<seq> pl <W>`, `<seq> lgc <MHz>`, `<seq> rgc` in `sweep/cmd.txt`) | administrator, so only with Power control on |
|
||||
| AMD | `igneum-gpu-telemetry --card N --set-plimit <offset>` (0 = default, -20 = 80%), inside the `tune` line's `plimit_range` | `--set-gmax <MHz>` inside `gmax_range`; `--reset` for the default point | not settable through ADLX on RDNA 4; read back as `mclk_mhz`, and a step whose mean memory clock falls under 95% of the baseline's is marked and cannot win | the helper, one process per request, exit 0 and a `tune ... ok` line | none on Windows (ADLX manual tuning); root on Linux, so measure only there |
|
||||
| AMD | `igneum-gpu-telemetry --card N --set-plimit <offset>` (0 = default, -20 = 80%), inside the `tune` line's `plimit_range` (PC 1's 9070 XT: -30 to 10, so 70% is the floor) | `--set-gmax` only when the `tune` line's `gmax_range` is absolute MHz (floor 0 or above); on RDNA 4 the range is an offset from stock (-500 to 1000 on PC 1) and the clock knob stays closed until the stock clock is known; `--reset` for the default point | not settable through ADLX on RDNA 4; read back as `mclk_mhz`, and a step whose mean memory clock falls under 95% of the baseline's is marked and cannot win | the helper, one process per request, exit 0 and a `tune ... ok` line | none on Windows (ADLX manual tuning); root on Linux, so measure only there |
|
||||
| Apple | none | none | none | measure only | none |
|
||||
|
||||
Vendor limits are never exceeded and the floor is never undercut: the plan clamps every point (`Limits::clamp_clock`,
|
||||
|
|
@ -151,7 +151,11 @@ measure, TUNE record, upload, aggregation, prior shape in a test manifest). The
|
|||
9070 XT run are owed: the 5090 the moment Power control is switched on (one prompt, then the tune runs by itself
|
||||
within 2 minutes of steady mining), the 9070 XT when the card is back on the bus.
|
||||
|
||||
(The run's numbers are appended below when the job reports.)
|
||||
Run 1 (ember-tune-pc1-1, 22:30 UTC): aborted 47 s in by the installed app quitting for the 0.3.11 update-now, before
|
||||
any step; nothing set; the "before" snapshots are in the bench log (5090: 450 W of 575, 2,850 MHz core, 3,090 MHz
|
||||
maximum, 14,001 MHz memory; 9070 XT present on bus 98 with OFFSET ranges `gmax_range -500 1000`, `plimit_range -30
|
||||
10`). The offset finding changed the AMD mapping (054e041): an offset clock range closes the clock knob and the power
|
||||
ladder runs on a percent scale bounded by `plimit_range`. The re-run follows the 0.3.11 rollout.
|
||||
|
||||