bench log: dry run 3 passed (the first measurement engine on PC 1 that mined: 5090 127.31 MH/s at 316.5 W, 4070 28.68 MH/s at 102.7 W), the folder-lock finding measured on PC 1 and its consequence
Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com>
This commit is contained in:
parent
0affb3c277
commit
27dfeec290
1 changed files with 9 additions and 0 deletions
|
|
@ -1660,6 +1660,15 @@ Branch `ember-tune` (54ff1bc), docs/plans/ember-tune.md. Every card tuned for MH
|
|||
|
||||
**Run 2, 6 October 2026, 07:21 to 07:56Z (job ember-tune-pc1-2, elevated on the project lead's word, engine 25113f52..., PC 1 on 0.3.11):** the project lead answered the one prompt; the installed app stopped its miners at 07:21:16Z; the second engine ran for the whole 35-minute budget at "waiting, 0.00 MH/s" and no step ran. Cause: the playbook wrote the engine's copy of settings.json with PowerShell 5.1's `Set-Content -Encoding utf8`, which adds a UTF-8 BOM; the engine's JSON parser refuses it, `Settings::load` fell back to defaults (no payout address, no cards), the engine logged `[error] no payout address` and never started a miner. Run 1's scratch log carried the same line the night before. Readbacks, idle both times: the 5090 at 90.6 W before and 69.9 W after (2,505 then 2,407 MHz core, 14,001 MHz memory, limit 450 W of 575), the 9070 XT at factory (`gmax 0`, `plimit 0`). Nothing set on either card. The installed app's runner released the miners-stopped hold by itself on the failed exit (`job finished; the miners restart` at 07:56:50Z, both miners up by 07:57:04Z, `mining` at 07:57:29Z): mining paused 36 min 13 s. Fix 8273494: the copy is written without a BOM, the address is read back and the job fails within seconds if it is empty (`RESULT TUNE scratch settings: address ..., cards N, first bytes ...`), and the CI check fails any playbook writing JSON with `Set-Content -Encoding utf8`. The re-run needs one more click on the prompt.
|
||||
|
||||
**Dry run 3, 6 October 2026, 14:56 to 15:02Z (job ember-dryrun-pc1-3, unelevated, no prompt, measure only; engine from ember-tune 07d5a72, kit sha256 36b522c9...):** the first measurement engine on PC 1 that mined. Both cards, one 60 s row each at the installed app's 80% cap, clocks unlocked, rate = the worker's STATUS wall rate, draw = nvidia-smi every 5 s:
|
||||
|
||||
| Card | MH/s | W | MH/W | core | memory | GPU C | limit |
|
||||
|---|---|---|---|---|---|---|---|
|
||||
| RTX 5090 | 127.31 | 316.5 | 0.402 | 2,850 MHz | 13,801 MHz | 68 | 460 W of 575 |
|
||||
| RTX 4070 | 28.68 | 102.7 | 0.279 | 2,805 MHz | 10,251 MHz | 46 | 160 W of 200 |
|
||||
|
||||
Nothing set; the installed app's miners back after 350 s. Why every earlier run (5 and 6 October, runs 1 to 4 and dry runs 1 and 2) read its copied settings as defaults, measured on PC 1 (collect ember-acl-2): the engine's own start locks its app folder with `icacls /inheritance:r /grant:r <user>:F`; cutting the folder's inheritance propagates down, the non-inheritable grant gives the children nothing, so a file COPIED in before the start (settings.json, machine-id, wallet.json) is left with no access entry and its owner cannot read it (`ReadAllText`: access denied), while the engine's own files written after the lock inherit fine, which hid it for a day. A first fix with `(OI)(CI)F /T` left the file empty too: `/T` re-applies `/inheritance:r` to each file after the propagation and an `(OI)(CI)` entry on a file is inherit-only. The right form is the inheritable grant without `/T` (07d5a72). Consequence for every tier on Windows: nothing changes for the installed app (its files were always its own); any tool that drops files into the app folder before the app starts (an installer's seed, a migration, a support script) was unreadable to the app until now and is readable from 0.3.13 on.
|
||||
|
||||
Consequence for the tiers: an AMD card is tuned on its power limit alone until its stock core clock is read (a 9070 XT at -30% is the floor the driver allows, 4 steps, 5 minutes); every NVIDIA card's two-knob plan waits on the user's one click on Power control; the re-run on PC 1 is held until the quit's source is named (the event-log collect) and follows the 0.3.11 rollout (the update clears the jobs folder, so the engine and the helper are fetched again), with the scheduler's slot.
|
||||
## 5 October 2026 (night), read width of the lottery hash: 4, 16 and 64-byte loads, a per-load mix, a written scratch; three cards (gate 1 experiment, cryptographer)
|
||||
|
||||
|
|
|
|||